Impact of breast density on the compression mammography and mean dose of glandular exposure during a digital mammography in patients undergoing a breast cancer screening program

Authors

  • Eduardo De Núbila CEDIUL S.A., Imágenes Diagnósticas y Terapéuticas. Barranquilla, Universidad Metropolitana de Barranquilla
  • María Victoria Erazo Universidad Metropolitana de Barranquilla
  • Favio Gómez Universidad Metropolitana de Barranquilla
  • Saray Serrano CEDIUL S.A., Imágenes Diagnósticas y Terapéuticas. Barranquilla, Universidad Metropolitana de Barranquilla
  • Israel Díaz-Yúnez CEDIUL S.A., Imágenes Diagnósticas y Terapéuticas. Barranquilla, Universidad Metropolitana de Barranquilla https://orcid.org/0000-0001-5633-2280
  • Guido Parra CEDIUL S.A., Imágenes Diagnósticas y Terapéuticas. Barranquilla, Universidad Metropolitana de Barranquilla https://orcid.org/0000-0003-3755-2741
  • Ana Tapia Médica radióloga. Directora de Posgrado de Radiología e imágenes diagnósticas, Universidad Metropolitana. Barranquilla

DOI:

https://doi.org/10.53903/01212095.310

Keywords:

Mammography, Breast density, Breast compression, Radiation dosage

Abstract

Objective: To evaluate the impact of breast density on the compression and dose of exposure of patients admitted to the breast cancer screening program with direct digital mammography. Material and Methods: Analytical observational study in patients who entered breast cancer
screening, between August and December 2019. All of them underwent standard mammographic views: craniocaudal (CC) and mediolateral oblique (MLO), with a Direct Digital Mammography equipment (Senographe Essential, GE). Patients with previous surgeries were excluded. The
thickness at the end of compression (mm), compression force (daN) and mean glandular dose (MGD) in mGy, were considered. The technique and interpretation (BI-RADS) were carried out by two technologists and two radiologists with more than 10 years of experience in breast image respectively. They were grouped into dense (C and D) and non-dense (A and B). The Mann-Whitney test was used to differentiate between means. For continuous quantitative, the correlation coefficient was used. A p<0.05 was considered significant. Results: A total of 478 breasts (239 patients) were evaluated. The average age was 56.8±8.4. When comparing the mammographic density with the thickness at the end of compression, this was significantly lower in dense breasts (C and D), compared with non-dense
(A and B): 58.4±9.1 vs 61.3±10.1mm; and 65.1±10.6 mm vs 68.1±11.4mm in CC and MLO views respectively (p<0.001, p=0.002). The compression force was significantly lower in dense breasts (7.9±1.0 daN), compared to non-dense (8.8±2.1daN), only in CC views (p <0.001). When evaluating the MGD, there was a significant direct correlation between thickness at the end of the compression and MGD (r2=0.21,p<0.001). In all projections, there were no significant differences between doses and breast
density (p=0.8). Conclusion: It is important to obtain a minimum thickness at the end of compression for a good image, especially in dense breast. However, it is not necessary to apply compression forces higher than the standard or exceed the degree of tolerance. Also there are no significant increased doses of glandular exposure in dense breasts with digital mammographic technique.

Downloads

Download data is not yet available.

References

Paredes ES. Atlas de la mamografía. Lippincott Williams & Wilkins; 2007.

D’Orsi CJ, Sickles EA, Mendelson EB, et al. ACR BI-RADS Atlas, Sistema de información y datos de imágenes de mama. Reston, VA, Colegio Americano de Radiología; 2013.

Barrionuevo Pérez N, Jordán Valenzuela M, Cordón Llera J. Mamografía. Libro de imagenología de mama. Tercera Edición. Colombia; 2015.

European Commission Protocol on Dosimetry in Mammography. EUR 16263 EN, 1996.

Andisco D, Blanco S, Buzz AE. Dosimetría en radiología. Rev Argent Radiol. 2014;78(2):65-124.

American College of Radiology, Committee on Quality Assurance in Mammography. Mammography quality control manual. Reston: American College of Radiology; 2011.

Instituto Nacional del Cáncer. Guía técnica de controles de calidad en mamografía. Buenos Aires: INC; 2015.

Giordano L, Gallo F, Petracci E, et al.; Andromeda working group. The ANDROMEDA prospective cohort study: predictive value of combined criteria to tailor breast cancer screening and new opportunities from circulating markers—study protocol. BMC

Cancer. 2017;17(1):785. https://bmccancer.biomedcentral.com/track/pdf/10.1186/s12885-017-3784-5.

Wanders JOP, Holland K, Karssemeijer N, et al. The effect of volumetric breast density on the risk of screendetected and interval breast cancers: a cohort study. Breast Cancer Res. 2017;19(1):67. https://breast-cancer-research. biomedcentral.com/track/pdf/10.1186/s13058-17-08599.

Elwood M, McNoe B, Smith T, et al. Once is enough—why some women do not continue to participate in a breast cancer screening programme. N Z Med J. 1998;111(1066):180-3.

Gobierno de Italia. Decreto legislativo 187 del 26 maggio 2000. Attuazione della direttiva 97/43/Euratom in materia di protezione sanitaria delle per sone contro i pericoli delle radiazioni ionizzanti connesse ad esposizioni mediche. G.U. 157 del 7 luglio 2000 Supplemento Ordinario n.◦ 105

Andisco D, Blanco S, Buzz AE. Dosimetría en radiología. Rev Argent Radiol. 2014;78: 114-7.

Groot JE, ten Voorde M, Branderhorst W, et al. What determines pain in mammographic breast compression [Poster]. 2012.

Henrot P, Boisserie-Lacroix M, Boute V, et al. Self-compression Technique vs Standard Compression in Mammography: A Randomized Clinical Trial. JAMA Intern Med. 2019(179):407-14.

Osorio C, Castrillón J. Estimacion del nivel de referencia en mamografía digital en el área metropolitana del Valle de Aburrá. Rev. Cienc. 2018(7):62-75.

Mercer CE, Szczepura K, Kelly J, et al. A 6-year study of mammographic compression force: practitioner variability within and between screening sites. Radiography. 2015;21(1):68-73.

Gemici AA, Arıbal E, Özaydın AN, et al. Comparación de las evaluaciones cualitativas y volumétricas de la densidad mamaria y análisis de los parámetros de compresión mamaria y el volumen mamario de las mujeres en el Proyecto de cribado mamógrafo de Bahcesehir. Eur J Salud. 2020; 16(2):110-6. https://doi.org/10.5152/ejbh.2020.4943.

Pike M, Krailo M, Henderson B, et al. ‘Hormonal’risk factors,‘breast tissue age’and the age-incidence of breast cancer. Nature. 1983;303(5920):767-70.

Couto E, Qureshi S, Hofvind S, et al. Hormone therapy use and mammographic density in postmenopausal Norwegian women. Breast Cancer Res Treat. 2012;132:297-305.

Mullooly M, Gierach G. The potential for mammographic breast density changes as a biosensor of adjuvant tamoxifen therapy adherence and response. JNCI Cancer Spectrum. 2018;2(4):72.

Boyd N, Martin L, Sun L, et al. Body size, mammographic density, and breast cancer risk. Cancer Epidemiol Prevent Biomark. 2006;15(11):2086-92.

Vachon C, Kuni C, Anderson K, et al. Association of mammographically defined percent breast density with epidemiologic risk factors for breast cancer (United States). Cancer Causes & Control. 2000;11(7):653-62.

Maskarinec G, Morimoto Y, Daida Y, et al. A comparison of breast density measures between mothers and adolescent daughters. BMC Cancer. 2011;11(1):1-10.

Published

2025-09-30

How to Cite

(1)
De Núbila, E.; Victoria Erazo, M.; Gómez, F.; Serrano, S.; Díaz-Yúnez, I.; Parra, G.; Tapia, A. Impact of Breast Density on the Compression Mammography and Mean Dose of Glandular Exposure During a Digital Mammography in Patients Undergoing a Breast Cancer Screening Program. Rev. colomb. radiol. 2025, 36, 6465-6469.
Article metrics
Abstract views165
Galley views55
PDF Views55
HTML views0
Other views0