Dose and Image Quality in Spectral Computed Tomography Compared to Helical Protocols

Authors

  • Nathaly Barbosa Fundación CTIC, Bogotá
  • Vanesa Vasco Fundación CTIC Bogotá
  • Fernando Rodriguez Fundación CTIC, Bogotá
  • Daniel Upegui Fundación CTIC, Bogotá https://orcid.org/0000-0002-5474-0982

DOI:

https://doi.org/10.53903/01212095.402

Keywords:

Radiation dose, Computed tomography, Dual-energy CT, Diagnostic reference levels

Abstract

Objectives: Dual-energy computed tomography (DECT) provides additional diagnostic information compared with conventional single-energy CT (SECT), particularly in oncology. This study aimed to calculate the typical dose values for DECT protocols and compare them with those of SECT, as well as to evaluate the image quality of both modalities. Methods: A retrospective analysis of DECT studies was conducted at an oncology institution. Typical radiation dose values (CTDIvol and DLP) were determined according to the ICRP 135 method. Image quality was assessed in a subset of abdominal studies by three radiologists using a predefined ordinal scale to evaluate noise, sharpness, and overall contrast. Results: The typical dose values for DECT were lower than those obtained with equivalent SECT protocols (CTDIvol: 7.69–9.37 mGy; DLP: 242–480 mGy·cm). Qualitative assessment showed that 95 % of the studies had minimal or mild noise, 98 % were rated as acceptable or higher in sharpness, and 96 % were rated as acceptable or higher in overall contrast. Conclusions: In our experience, DECT did not result in an increased radiation dose compared with SECT and provided additional  diagnostic information with adequate image quality. These findings support the use of DECT as a clinically feasible alternative that balances radiation dose and image quality.

Downloads

Download data is not yet available.

References

Kong D, Chen X, Gao P, Zhao K, Zheng C, Zhou H. Diagnostic accuracy of contrastenhanced dual-energy computed tomography for detecting metastatic lymph nodes in patients with malignant tumors: a systematic review and meta-analysis. Quant Imaging Med Surg. 2023;13(5):3050-65.

Wang T, Fan Z, Zou L, Hou Y. Can quantitative parameters of spectral computed tomography predict lymphatic metastasis in lung cancer? a systematic review and meta-analysis. Radiother Oncol. 2023;183:109643. https://doi.org/10.1016/j.radonc.2023.109643.

Chen M, Jiang Y, Zhou X, Wu D, Xie Q. Dual-energy computed tomography in detecting and predicting lymph node metastasis in malignant tumor patients: a comprehensive review. Diagnostics (Basel). 2024;14(4):377. https://doi.org/10.3390/diagnostics14040377.

Vañó E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M, et al. ICRP Publication 135: Diagnostic reference levels in medical imaging. Ann ICRP [Internet]. 2017;46(1):1-144. Disponible en: http://journals.sagepub.com/doi/10.1177/0146645317717209

Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology. 2017;284(1):120-33.

Cadavid L, Karout L, Kalra MK, Morgado F, Londoño MA, Pérez L, et al. Setting up regional diagnostic reference levels for pediatric computed tomography in Latin America: preliminary results, challenges and the work ahead. Pediatr Radiol. 2024;54(3):457-67.

Oliveira Bernardo M, Karout L, Morgado F, Ebrahimian S, Sarmet Santos A, Amorim C, et al. Establishing national clinical diagnostic reference levels and achievable doses for CT examinations in Brazil: A prospective study. Eur J Radiol. 2023:169:111191. https://doi.org/10.1016/j.ejrad.2023.111191.

McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and Multi-Energy CT: principles, technical approaches, and clinical applications. Radiology. 2015;276(3):637-53.

Uhrig M, Simons D, Kachelrieß M, Pisana F, Kuchenbecker S, Schlemmer HP. Advanced abdominal imaging with dual energy CT is feasible without increasing radiation dose. Cancer Imaging. 2016;16(1):15.

Schmidt D, Söderberg M, Nilsson M, Lindvall H, Christoffersen C, Leander P. Evaluation of image quality and radiation dose of abdominal dual-energy CT. Acta Radiol. 2018;59(7):845-52.

Wortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol. 2020;27(1):45-50.

Lenga L, Leithner D, Peterke JL, Albrecht MH, Gudauskas T, D’Angelo T, et al. Comparison of radiation dose and image quality of contrast-enhanced dual-source CT of the chest: single-versus dual-energy and second-versus third-generation technology. AJR Am J Roentgenol. 2019;212(4):741-7.

Ahmad M, Jacobsen MC, Thomas MA, Chen HS, Layman RR, Jones AK. A Benchmark for automatic noise measurement in clinical computed tomography. Med Phys. 2021;48(2):640-7.

Published

2025-03-30

How to Cite

(1)
Barbosa, N.; Vasco, V.; Rodriguez, F.; Upegui, D. Dose and Image Quality in Spectral Computed Tomography Compared to Helical Protocols. Rev. colomb. radiol. 2025, 36, 6325-6331.

Issue

Section

Research articles
Article metrics
Abstract views611
Galley views252
PDF Views252
HTML views0
Other views0

Some similar items: